Project pricing at Plumbing-Deals is tailored to meet your specific project. The size of a plumbing job that qualifies as a project can vary, generally its larger than a single bathroom or kitchen remodel. By submitting the form or calling, you're taking the first step towards receiving a customized quote that considers your project's scope, timeline, and budget, ensuring a seamless and cost-effective solution for your plumbing parts and supplies.
Ready to get started? Call us at 888-682-5956, and let's make your plumbing project a success!
- Condition:
- New
- Availability:
- Limited Stock! Ships next business day
- Shipping:
- Free Shipping
Honeywell S8610U3009 Universal Intermittent Pilot Control Module (One or Two Rods) has continuous retry trial time, configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge.
Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Honeywell S8610U3009 provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances.
Features:
Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances
Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
For use with Natural or LP gas
For use in single rod or dual rod/remote sense applications. Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended
Functional equivalent of S86, S8600, S8610 and S90 modules
Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable
Technical Specifications:
Ignition System Type: Intermittent Pilot
Ignition Sequence: Continous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
Typical Gas Control: VR8204, VR8304
Type of Gas: Natural or LP
Flame Sense: Single Rod or Two Rods
Ignition Source: Internal high voltage spark generator
PrePurge: Configurable to 30 seconds or no prepurge
Ignition Trials To Lockout: continuous retry
Lockout Timing: Configurable to 15 seconds or 90 seconds
Ignition Trial Time (sec): continuous retry
Maximum Valve Load @ 24 Vac (Amps): 1A Pilot, 2A Main @ 165F; 1A Pilot, 1A Main @ 175F
Typical Ignition Hardware: Q345, Q3451, Q3452
Dimensions: 3-15/16" high x 5-7/16" wide x 2-5/8" deep
Electrical Ratings: 24 Vac
Frequency: 60 Hz
Frequency: 50 Hz
Maximum Ambient Temperature: -40F to +165F
Approvals, Canadian Standards Association: Design Certified
Includes: Damper connection with automatic vent damper plug
Tradeline Value: Super Tradeline
Between Trial Time (sec): 5 minute delay after failed trial for ignition
Flame Failure Response Time (sec): 2 seconds maximum