The Honeywell L8148E1299 Aquastat Relay Immersion Type Controller is an immersion-type controller that combines high limit protection with switching relay control of burner and circulator motors.

Features:

  • High limit opens burner circuit only.
  • Select models include transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.

Specifications:

  • Hazmat Information: UN1294 Toluene
  • Application: High Limit
  • Dimensions (in.): 6-1/8 in. high x 4-5/16 in. wide x 3-1/8 in. deep
  • Maximum Safe Operating Pressure (psi): Immersion Well: 255 psi
  • Maximum Safe Operating Pressure (kPa): Immersion Well: 1757 kPa
  • Temperature Range (F) Maximum--150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V load
  • Temperature Range (C) Maximum--66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V load
  • Includes 50 VA transformer
  • Mounting Vertical Mount
  • Electrical Ratings Low Voltage: 0.8 A max. @ 24 Vac; 0.25 A @ 0.25 to 12 Vdc; At Locked Rotor-- 44.4A @ 120 Vac: 22.2A @ 240 Vac
  • Frequency 60 Hz
  • Approvals, Underwriters Laboratories Inc. UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.
  • Approvals, CSA Certified: File No. LR95329-1
  • Electrical Connections: Quick-Connect / Screw
  • Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
  • Voltage: 120 Vac
  • Operating Temperature Range (F): High Limit-- 180 F to 240 F
  • Operating Temperature Range (C): High Limit-- 82 C to 116 C
  • Differential Temperature (F): 15 F fixed
  • Switching Action: SPST: High Limit & Circulator
  • Anticipator Setting: 0.2 A
  • Capillary Length (in.): 4-1/2 in.
  • Insulation Depth (in.): 1-1/2 in. to 3 in. less well
  • Insulation Depth (mm): 38 mm to 76 mm less well
  • Capillary Length (mm): 114 mm

Electrical Ratings (Burner):

  • At Full Load-- Low Voltage: 0.8 A max. @ 24 Vac: Line Voltage: 7.4 A @ 120 Vac: 3.7 A @ 240 Vac
  • At Locked Rotor-- Line Voltage: 44.4 A @ 120 Vac: 22.7 A @ 240 Vac; Millivolt--0.25 A @ 1/4 to 12 Vdc

Electrical Ratings, Circulator:

  • At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac
  • At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac