{"product_id":"new-yorker-cgs-c-steam-series-70-000-btu-steam-boiler-cgs30cni-h","title":"New Yorker CGS-C Steam Series 70,000 BTU Steam Boiler - CGS30CNI-H","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CGS-C CGS30CNI-H 70,000 BTU Cast-Iron Steam Boiler\u003c\/h2\u003e\n\u003cp\u003e\nWant classic steam heat that’s simple and dependable? The \u003cstrong\u003eNew Yorker CGS‑C CGS30CNI‑H\u003c\/strong\u003e is a compact, \n\u003cstrong\u003echimney‑vented gas steam boiler\u003c\/strong\u003e that brings proven cast‑iron durability and easy service to smaller homes and apartments. With \u003cstrong\u003eup to 81.9% AFUE\u003c\/strong\u003e, \u003cstrong\u003eelectronic ignition\u003c\/strong\u003e, and a factory \u003cstrong\u003event damper\u003c\/strong\u003e, it’s designed to cut standby losses compared with older standing‑pilot units—while delivering dry, even steam to your radiators.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS30CNI‑H (CGS‑C Steam Series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired \u003cstrong\u003eSteam\u003c\/strong\u003e Boiler, Cast Iron, Category I Natural Draft (Chimney Vent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e \u003cstrong\u003e69,000 BTU\/h\u003c\/strong\u003e (70,000 BTU class)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e \u003cstrong\u003e56,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Steam):\u003c\/strong\u003e \u003cstrong\u003e42,000 BTU\/h\u003c\/strong\u003e (≈ \u003cstrong\u003e175 sq. ft. EDR\u003c\/strong\u003e)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e Up to \u003cstrong\u003e81.9%\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent) with factory vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Built‑in draft diverter; \u003cstrong\u003e4\" flue\u003c\/strong\u003e to a lined masonry or listed metal chimney\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSteam Supply \/ Return Tappings:\u003c\/strong\u003e \u003cstrong\u003e2\"\u003c\/strong\u003e NPT (each)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e \u003cstrong\u003e3\/4\"\u003c\/strong\u003e NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; Controls:\u003c\/strong\u003e Probe‑type \u003cstrong\u003eLWCO\u003c\/strong\u003e, pressure limit control, \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e, blocked‑vent \u0026amp; rollout switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~\u003cstrong\u003e12‑3\/4\" × 28\" × 40‑7\/16\"\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cstrong\u003e10‑Year Limited\u003c\/strong\u003e heat exchanger (residential; see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eProven Cast Iron Steam Performance\u003c\/h4\u003e\n\u003cp\u003e\nThe CGS‑C’s \u003cstrong\u003ecast‑iron heat exchanger\u003c\/strong\u003e, stainless steel burners, and \u003cstrong\u003emetal section connectors\u003c\/strong\u003e deliver long service life and steady, dry steam—ideal for one‑pipe and two‑pipe radiator systems.\n\u003c\/p\u003e\n\n\u003ch4\u003eRight‑Sized For Smaller Homes\u003c\/h4\u003e\n\u003cp\u003e\nWith a \u003cstrong\u003e42,000 BTU\/h Net IBR\u003c\/strong\u003e rating (about \u003cstrong\u003e175 sq. ft. EDR\u003c\/strong\u003e), this model is a smart match for compact homes and apartments when sized to your connected radiation. That helps radiators heat evenly without short‑cycling.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple, Code‑Compliant Chimney Venting\u003c\/h4\u003e\n\u003cp\u003e\nA built‑in \u003cstrong\u003edraft diverter\u003c\/strong\u003e keeps the jacket low for tight basements, and the boiler vents to a properly lined chimney with a standard \u003cstrong\u003e4‑inch flue\u003c\/strong\u003e for straightforward replacements.\n\u003c\/p\u003e\n\n\u003ch4\u003eFuel‑Saving Ignition \u0026amp; Vent Damper\u003c\/h4\u003e\n\u003cp\u003e\nThe boiler’s \u003cstrong\u003eelectronic ignition\u003c\/strong\u003e fires only on a call for heat, and the factory \u003cstrong\u003event damper\u003c\/strong\u003e helps reduce standby losses—key efficiency upgrades versus older standing‑pilot steam boilers.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller‑Friendly Near‑Boiler Piping\u003c\/h4\u003e\n\u003cp\u003e\nLarge \u003cstrong\u003e2‑inch\u003c\/strong\u003e supply and return tappings support clean headers and equalizers for better steam quality. Standard safety controls include a \u003cstrong\u003elow water cut‑off\u003c\/strong\u003e, \u003cstrong\u003epressure limit\u003c\/strong\u003e, and \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e.\n\u003c\/p\u003e","brand":"NEW YORKER","offers":[{"title":"Default Title","offer_id":43931892973619,"sku":"BURCGS30CNIH","price":3726.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/2_CGS-C-Steam-Series.png?v=1771884123","url":"https:\/\/plumbing-deals.com\/products\/new-yorker-cgs-c-steam-series-70-000-btu-steam-boiler-cgs30cni-h","provider":"Plumbing Deals","version":"1.0","type":"link"}