{"title":"New Yorker","description":"\u003cp\u003eNew Yorker Boiler Company provides dependable residential heating solutions designed for comfort and low project costs. They offer durable cast-iron and robust steel boilers, with versatile gas- and oil-fired options to meet any heating need. \u003c\/p\u003e","products":[{"product_id":"new-yorker-cgs-c-steam-series-70-000-btu-steam-boiler-cgs30cni-h","title":"New Yorker CGS-C Steam Series 70,000 BTU Steam Boiler - CGS30CNI-H","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CGS-C CGS30CNI-H 70,000 BTU Cast-Iron Steam Boiler\u003c\/h2\u003e\n\u003cp\u003e\nWant classic steam heat that’s simple and dependable? The \u003cstrong\u003eNew Yorker CGS‑C CGS30CNI‑H\u003c\/strong\u003e is a compact, \n\u003cstrong\u003echimney‑vented gas steam boiler\u003c\/strong\u003e that brings proven cast‑iron durability and easy service to smaller homes and apartments. With \u003cstrong\u003eup to 81.9% AFUE\u003c\/strong\u003e, \u003cstrong\u003eelectronic ignition\u003c\/strong\u003e, and a factory \u003cstrong\u003event damper\u003c\/strong\u003e, it’s designed to cut standby losses compared with older standing‑pilot units—while delivering dry, even steam to your radiators.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS30CNI‑H (CGS‑C Steam Series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired \u003cstrong\u003eSteam\u003c\/strong\u003e Boiler, Cast Iron, Category I Natural Draft (Chimney Vent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e \u003cstrong\u003e69,000 BTU\/h\u003c\/strong\u003e (70,000 BTU class)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e \u003cstrong\u003e56,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Steam):\u003c\/strong\u003e \u003cstrong\u003e42,000 BTU\/h\u003c\/strong\u003e (≈ \u003cstrong\u003e175 sq. ft. EDR\u003c\/strong\u003e)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e Up to \u003cstrong\u003e81.9%\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent) with factory vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Built‑in draft diverter; \u003cstrong\u003e4\" flue\u003c\/strong\u003e to a lined masonry or listed metal chimney\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSteam Supply \/ Return Tappings:\u003c\/strong\u003e \u003cstrong\u003e2\"\u003c\/strong\u003e NPT (each)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e \u003cstrong\u003e3\/4\"\u003c\/strong\u003e NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; Controls:\u003c\/strong\u003e Probe‑type \u003cstrong\u003eLWCO\u003c\/strong\u003e, pressure limit control, \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e, blocked‑vent \u0026amp; rollout switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~\u003cstrong\u003e12‑3\/4\" × 28\" × 40‑7\/16\"\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e \u003cstrong\u003e10‑Year Limited\u003c\/strong\u003e heat exchanger (residential; see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eProven Cast Iron Steam Performance\u003c\/h4\u003e\n\u003cp\u003e\nThe CGS‑C’s \u003cstrong\u003ecast‑iron heat exchanger\u003c\/strong\u003e, stainless steel burners, and \u003cstrong\u003emetal section connectors\u003c\/strong\u003e deliver long service life and steady, dry steam—ideal for one‑pipe and two‑pipe radiator systems.\n\u003c\/p\u003e\n\n\u003ch4\u003eRight‑Sized For Smaller Homes\u003c\/h4\u003e\n\u003cp\u003e\nWith a \u003cstrong\u003e42,000 BTU\/h Net IBR\u003c\/strong\u003e rating (about \u003cstrong\u003e175 sq. ft. EDR\u003c\/strong\u003e), this model is a smart match for compact homes and apartments when sized to your connected radiation. That helps radiators heat evenly without short‑cycling.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple, Code‑Compliant Chimney Venting\u003c\/h4\u003e\n\u003cp\u003e\nA built‑in \u003cstrong\u003edraft diverter\u003c\/strong\u003e keeps the jacket low for tight basements, and the boiler vents to a properly lined chimney with a standard \u003cstrong\u003e4‑inch flue\u003c\/strong\u003e for straightforward replacements.\n\u003c\/p\u003e\n\n\u003ch4\u003eFuel‑Saving Ignition \u0026amp; Vent Damper\u003c\/h4\u003e\n\u003cp\u003e\nThe boiler’s \u003cstrong\u003eelectronic ignition\u003c\/strong\u003e fires only on a call for heat, and the factory \u003cstrong\u003event damper\u003c\/strong\u003e helps reduce standby losses—key efficiency upgrades versus older standing‑pilot steam boilers.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller‑Friendly Near‑Boiler Piping\u003c\/h4\u003e\n\u003cp\u003e\nLarge \u003cstrong\u003e2‑inch\u003c\/strong\u003e supply and return tappings support clean headers and equalizers for better steam quality. Standard safety controls include a \u003cstrong\u003elow water cut‑off\u003c\/strong\u003e, \u003cstrong\u003epressure limit\u003c\/strong\u003e, and \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e.\n\u003c\/p\u003e","brand":"NEW YORKER","offers":[{"title":"Default Title","offer_id":43931892973619,"sku":"BURCGS30CNIH","price":3726.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/2_CGS-C-Steam-Series.png?v=1771884123"},{"product_id":"new-yorker-cg30-fngh-cg-30-dni-g2-62-000-btu-hot-water-boiler","title":"New Yorker CG30-FNGH (CG 30 DNI-G2) 62,000 BTU Hot Water Boiler","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CG30-FNGH (CG 30 DNI-G2) 62,000 BTU Cast-Iron Hot Water Gas Boiler\u003c\/h2\u003e\n\n\u003cp\u003e\nLooking for dependable whole‑home heat with easy service? The \u003cstrong\u003eNew Yorker CG30\u003c\/strong\u003e is a compact, \n\u003cstrong\u003ecast‑iron, chimney‑vented hot water boiler\u003c\/strong\u003e with straightforward controls and proven durability—great for baseboard and radiator systems in small to mid‑size homes. An integrated control with a fuel‑saving \u003cstrong\u003ethermal purge\u003c\/strong\u003e routine helps trim standby losses, while electronic ignition fires only when there’s a call for heat.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CG30‑FNGH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired, Non‑Condensing Hot Water Boiler (Cast Iron, Category I, Chimney Vent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available on select packages)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e 62,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e 52,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Water):\u003c\/strong\u003e 45,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e 82.6%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent); step‑opening gas valve for smooth starts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Category I, draft‑hood; \u003cstrong\u003e4\" flue\u003c\/strong\u003e to a lined masonry or listed metal chimney (typical minimum 4\" × 15 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Connections:\u003c\/strong\u003e 1‑1\/4\" NPT supply \u0026amp; return\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz, 1‑phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~14\" × 32\" × 40\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncluded:\u003c\/strong\u003e Integrated boiler control with \u003cstrong\u003ethermal purge\u003c\/strong\u003e, factory vent damper; many packages include a \u003cstrong\u003eTaco 007\u003c\/strong\u003e circulator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Limited lifetime heat exchanger (residential); 1‑year parts (see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eReliable Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003e\nA heavy‑duty \u003cstrong\u003ecast‑iron heat exchanger\u003c\/strong\u003e and metal section connectors deliver long service life and consistent heat transfer—ideal for hydronic systems that run for decades.\n\u003c\/p\u003e\n\n\u003ch4\u003eFuel‑Saving Integrated Control\u003c\/h4\u003e\n\u003cp\u003e\nThe user‑friendly control includes an \u003cstrong\u003eenergy‑saving thermal purge\u003c\/strong\u003e that circulates residual warm water before firing the burner, helping reduce fuel use and chimney losses.\n\u003c\/p\u003e\n\n\u003ch4\u003eRight‑Sized For Typical Homes\u003c\/h4\u003e\n\u003cp\u003e\nWith a \u003cstrong\u003eNet IBR of about 45,000 BTU\/h\u003c\/strong\u003e, the CG30 is a solid match for many smaller homes and well‑insulated spaces when properly sized to your radiation and heat loss.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple, Code‑Compliant Venting\u003c\/h4\u003e\n\u003cp\u003e\nThis \u003cstrong\u003eCategory I natural‑draft\u003c\/strong\u003e boiler connects to a properly sized, lined chimney with a standard \u003cstrong\u003e4‑inch flue\u003c\/strong\u003e. That makes replacements straightforward in homes with existing chimneys.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller‑Friendly Layout\u003c\/h4\u003e\n\u003cp\u003e\nClear front\/side access, 1‑1\/4\" supply\/return tappings, and included vent damper simplify piping and annual service. Many packages ship with a familiar \u003cstrong\u003eTaco 007\u003c\/strong\u003e circulator to speed up installs.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color: #3366ff;\"\u003e\u003ca href=\"https:\/\/s3-us-west-2.amazonaws.com\/catsy.782\/CG-F+IO.PDF\" target=\"_blank\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eInstallation and Operation Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"color: #3366ff;\"\u003e\u003ca href=\"https:\/\/s3-us-west-2.amazonaws.com\/catsy.782\/CG-F+Product+Specifications.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eSpec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"color: #3366ff;\"\u003e\u003ca href=\"https:\/\/s3-us-west-2.amazonaws.com\/catsy.782\/New+Yorker+Limited+Warranty.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eWarranty\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"NEW YORKER","offers":[{"title":"Default Title","offer_id":43935260508211,"sku":"BURCG30FNGH","price":3061.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcg70fngh__1.png?v=1770281328"},{"product_id":"new-yorker-cgs60-cnih-cgs-60-ani-me-2-175-000-btu-steam-boiler","title":"New Yorker CGS60-CNIH (CGS 60 ANI-ME 2) 175,000 BTU Steam Boiler","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CGS60‑CNIH (CGS 60 ANI‑ME 2) 175,000 BTU Cast‑Iron Steam Boiler\u003c\/h2\u003e\n\n\u003cp\u003e\nLooking for dependable \u003cstrong\u003eresidential steam heat\u003c\/strong\u003e with straightforward service? The \u003cstrong\u003eNew Yorker CGS60‑CNIH\u003c\/strong\u003e is a compact, \n\u003cstrong\u003echimney‑vented gas steam boiler\u003c\/strong\u003e that pairs proven \u003cstrong\u003ecast‑iron\u003c\/strong\u003e durability with modern efficiency touches like \u003cstrong\u003eelectronic ignition\u003c\/strong\u003e and a factory \u003cstrong\u003event damper\u003c\/strong\u003e. A built‑in \u003cstrong\u003edraft diverter\u003c\/strong\u003e keeps the jacket height low for tight basements, and large \u003cstrong\u003e2‑inch steam tappings\u003c\/strong\u003e help deliver \u003cstrong\u003edry, even steam\u003c\/strong\u003e to classic one‑pipe or two‑pipe radiator systems.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS60CNI-H \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired Steam Boiler, Cast Iron, Natural Draft (Chimney Vent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e 172,000 BTU\/h (175,000 BTU class)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e 142,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Steam):\u003c\/strong\u003e 107,000 BTU\/h (≈ 445 sq. ft. EDR)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e Up to 82.1%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent) with factory vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Built‑in draft diverter; 6\" flue to a lined masonry or listed metal chimney\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSteam Supply \/ Return Tappings:\u003c\/strong\u003e 2\" NPT (each)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e 3\/4\" NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Content:\u003c\/strong\u003e 9.3 gallons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~22‑1\/2\" × 28\" × 40‑7\/16\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ASME H‑stamped, AHRI \u0026amp; ETL listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10‑Year Limited heat exchanger (residential; see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eBuilt For Dry, Even Steam\u003c\/h4\u003e\n\u003cp\u003e\nLarge \u003cstrong\u003e2‑inch supply and return tappings\u003c\/strong\u003e make it easier to pipe a proper header and equalizer—key to reducing carryover and helping radiators heat quietly and evenly. That’s a practical edge versus smaller‑tapped boilers.\n\u003c\/p\u003e\n\n\u003ch4\u003eLow‑Profile Jacket For Tight Basements\u003c\/h4\u003e\n\u003cp\u003e\nA factory \u003cstrong\u003edraft diverter\u003c\/strong\u003e is integrated into the boiler jacket, so there’s no tall external draft hood. The result is a lower overall height that fits \u003cstrong\u003elow‑ceiling mechanical rooms\u003c\/strong\u003e and many basement retrofits.\n\u003c\/p\u003e\n\n\u003ch4\u003eFuel‑Saving Ignition \u0026amp; Vent Damper\u003c\/h4\u003e\n\u003cp\u003e\nThe CGS‑C’s \u003cstrong\u003eelectronic ignition\u003c\/strong\u003e fires only on a call for heat, and the \u003cstrong\u003emotorized vent damper\u003c\/strong\u003e helps cut standby losses up the chimney—meaning less wasted fuel compared with older standing‑pilot steam boilers.\n\u003c\/p\u003e\n\n\u003ch4\u003eProven Cast‑Iron Durability\u003c\/h4\u003e\n\u003cp\u003e\nA rugged \u003cstrong\u003ecast‑iron heat exchanger\u003c\/strong\u003e, stainless steel burners, and metal section connectors are designed for long service life. The boiler is \u003cstrong\u003eASME H‑stamped\u003c\/strong\u003e and AHRI listed for peace of mind.\n\u003c\/p\u003e\n\n\u003ch4\u003eRight‑Sized For Larger Homes \u0026amp; Multi‑Radiator Systems\u003c\/h4\u003e\n\u003cp\u003e\nWith a \u003cstrong\u003e107,000 BTU\/h Net IBR\u003c\/strong\u003e (about \u003cstrong\u003e445 sq. ft. EDR\u003c\/strong\u003e), this model is a strong match for many larger homes when sized to your connected radiation—ample output without oversizing.\n\u003c\/p\u003e","brand":"New Yorker","offers":[{"title":"Default Title","offer_id":43935260999731,"sku":"BURCGS60CNIH","price":4847.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcgs60cnih__1_646ba049-a39e-4fe7-b7eb-ff1f43acf8a6.png?v=1770280168"},{"product_id":"new-yorker-cg70-fngh-cg-70-dni-g2-198-000-btu-hot-water-boiler","title":"New Yorker CG70-FNGH (CG 70 DNI-G2) 198,000 BTU Hot Water Boiler","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CG70‑FNGH (CG 70 DNI‑G2) 198,000 BTU Cast‑Iron Hot Water Gas Boiler\u003c\/h2\u003e\n\u003cp\u003e\nNeed dependable whole‑home heat with easy service? The \u003cstrong\u003eNew Yorker CG70\u003c\/strong\u003e is a compact,\n\u003cstrong\u003ecast‑iron, chimney‑vented hot water boiler\u003c\/strong\u003e with straightforward controls and proven durability—ideal for baseboard and radiator systems. An integrated control with a fuel‑saving \u003cstrong\u003ethermal purge\u003c\/strong\u003e routine helps trim standby losses, while electronic ignition fires only when there’s a call for heat.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CG70‑FNGH (CG 70 DNI‑G2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired, Non‑Condensing Hot Water Boiler\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available on select packages)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e \u003cstrong\u003e198,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e \u003cstrong\u003e163,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Water):\u003c\/strong\u003e \u003cstrong\u003e142,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e \u003cstrong\u003e82%\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent); step‑opening gas valve for smooth starts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Category I, draft‑hood; \u003cstrong\u003e7\" flue\u003c\/strong\u003e to a lined masonry or listed metal chimney\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Connections:\u003c\/strong\u003e 1‑1\/4\" NPT supply \u0026amp; return\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e 3\/4\" NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz, 1‑phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~34‑1\/2\" × 24‑1\/2\" × 31‑1\/8\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncluded:\u003c\/strong\u003e Integrated boiler control with \u003cstrong\u003ethermal purge\u003c\/strong\u003e, factory vent damper; many packages include a \u003cstrong\u003eTaco 007\u003c\/strong\u003e circulator\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Limited lifetime heat exchanger (residential); 1‑year parts (see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eReliable Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003e\nA heavy‑duty \u003cstrong\u003ecast‑iron heat exchanger\u003c\/strong\u003e and metal section connectors deliver long service life and consistent heat transfer—ideal for hydronic systems that run for decades.\n\u003c\/p\u003e\n\n\u003ch4\u003eFuel‑Saving Integrated Control\u003c\/h4\u003e\n\u003cp\u003e\nThe user‑friendly control includes an \u003cstrong\u003eenergy‑saving thermal purge\u003c\/strong\u003e that circulates residual warm water before firing the burner, helping reduce fuel use and chimney losses.\n\u003c\/p\u003e\n\n\u003ch4\u003eRight‑Sized For Larger Homes\u003c\/h4\u003e\n\u003cp\u003e\nWith a \u003cstrong\u003eNet IBR of about 142,000 BTU\/h\u003c\/strong\u003e, the CG70 is a strong match for many larger homes when properly sized to your radiation and heat loss.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple, Code‑Compliant Venting\u003c\/h4\u003e\n\u003cp\u003e\nThis \u003cstrong\u003eCategory I natural‑draft\u003c\/strong\u003e boiler connects to a properly sized, lined chimney with a standard \u003cstrong\u003e7‑inch flue\u003c\/strong\u003e. That makes replacements straightforward in homes with existing chimneys.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller‑Friendly Layout\u003c\/h4\u003e\n\u003cp\u003e\nClear front\/side access, 1‑1\/4\" supply\/return tappings, and an included vent damper simplify piping and annual service. Many packages ship with a familiar \u003cstrong\u003eTaco 007\u003c\/strong\u003e circulator to speed up installs.\n\u003c\/p\u003e\n\n\u003cbr\u003e\u003cp\u003eWant to learn more about this hydronic boiler? Read our blog on factors to consider before purchasing a hydronic boiler, pros and cons of hydronic boilers, \u003ca href=\"https:\/\/plumbing-deals.com\/plumbing-blog\/pumps-water-heaters-and-boilers-hydronic-boilers\/\"\u003eand hydronic boiler recommendations.\u003c\/a\u003e\u003c\/p\u003e\u003cbr\u003e","brand":"New Yorker","offers":[{"title":"Default Title","offer_id":43935260966963,"sku":"BURCG70FNGH","price":4669.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcg70fngh__1_651a57b5-6ada-49e6-86ae-e31b1b8c766b.png?v=1770280168"},{"product_id":"new-yorker-cgs70-cnih-cgs-70-ani-me-2-210-000-btu-steam-boiler","title":"New Yorker CGS70-CNIH (CGS 70 ANI-ME 2) 210,000 BTU Steam Boiler","description":"\u003ch2\u003ePowerful Steam Heating: Introducing the New Yorker CGS70-CNIH Boiler\u003c\/h2\u003e\n\u003cp\u003e\nNeed dependable \u003cstrong\u003eresidential steam heat\u003c\/strong\u003e for cast‑iron radiators? The \u003cstrong\u003eNew Yorker CGS70‑CNIH\u003c\/strong\u003e is a 7‑section, \u003cstrong\u003egas‑fired steam boiler\u003c\/strong\u003e designed for steady performance, straightforward service, and long life. With an \u003cstrong\u003e82% AFUE\u003c\/strong\u003e, durable \u003cstrong\u003ecast iron heat exchanger\u003c\/strong\u003e, and a factory vent damper, this model delivers reliable steam while helping reduce standby losses—an ideal replacement choice for homes with existing steam systems.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS70‑CNIH (CGS 70 ANI‑ME 2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired Steam Boiler, Category I Natural Draft (Chimney Vent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (field‑convertible to LP with kit; up to 2,000 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e 207,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e 171,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR Rating (Steam):\u003c\/strong\u003e 128,000 BTU\/h  (≈ \u003cstrong\u003e533 sq. ft. EDR\u003c\/strong\u003e)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e 82.1%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent), with factory vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Chimney vent; built‑in draft diverter\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlue Collar:\u003c\/strong\u003e 7\" dia (recommended minimum chimney: 7\" × 15 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger:\u003c\/strong\u003e Cast Iron Sections with Metal Section Connectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Capacity:\u003c\/strong\u003e 10.7 gallons\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e 2\" steam supply \/ 2\" return; 3\/4\" NPT gas\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz, 15A (fused)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 25‑3\/4\" × 30\" × 40‑7\/16\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControls \u0026amp; Safety:\u003c\/strong\u003e Probe‑type LWCO, pressure limit control, 15 psi safety valve; blocked‑vent and rollout safety switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10‑Year Limited Heat Exchanger Warranty (residential)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eReliable Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003e\nThe CGS70‑CNIH uses heavy‑duty \u003cstrong\u003ecast iron sections\u003c\/strong\u003e with \u003cstrong\u003emetal section connectors\u003c\/strong\u003e to resist chemical attack and thermal stress—key advantages in steam applications that run for decades.\n\u003c\/p\u003e\n\n\u003ch4\u003eSteam Output You Can Size\u003c\/h4\u003e\n\u003cp\u003e\nRated at \u003cstrong\u003e128,000 BTU\/h Net IBR\u003c\/strong\u003e (about \u003cstrong\u003e533 sq. ft. EDR\u003c\/strong\u003e), this model provides consistent steam to radiators throughout typical mid‑size homes. The \u003cstrong\u003e82.1% AFUE\u003c\/strong\u003e efficiency helps manage gas costs without sacrificing comfort.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple Chimney Venting\u003c\/h4\u003e\n\u003cp\u003e\nAs a \u003cstrong\u003eCategory I natural‑draft\u003c\/strong\u003e boiler with a built‑in draft diverter, the CGS70‑CNIH installs on a standard lined masonry or listed metal chimney. A \u003cstrong\u003e7\" flue collar\u003c\/strong\u003e and a recommended minimum chimney height of \u003cstrong\u003e15 ft\u003c\/strong\u003e make venting straightforward for replacements.\n\u003c\/p\u003e\n\n\u003ch4\u003eElectronic Ignition \u0026amp; Built‑In Safety\u003c\/h4\u003e\n\u003cp\u003e\nAn \u003cstrong\u003eelectronic (intermittent) ignition\u003c\/strong\u003e lights the burner only when there’s a call for heat, and the factory \u003cstrong\u003event damper\u003c\/strong\u003e helps cut standby losses. Standard protections include a \u003cstrong\u003eprobe‑type low water cut‑off (LWCO)\u003c\/strong\u003e, \u003cstrong\u003epressure limit control\u003c\/strong\u003e, \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e, plus \u003cstrong\u003eblocked‑vent\u003c\/strong\u003e and \u003cstrong\u003erollout\u003c\/strong\u003e switches.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller‑Friendly Piping \u0026amp; Layout\u003c\/h4\u003e\n\u003cp\u003e\nWith \u003cstrong\u003e2\" steam supply\/return\u003c\/strong\u003e tappings, clear service access, and a compact \u003cstrong\u003e40‑7\/16\" height\u003c\/strong\u003e, this 7‑section boiler fits common near‑boiler piping layouts and tight mechanical rooms for faster, cleaner installs.\n\u003c\/p\u003e\n\n\u003ch4\u003eLP Conversion Option\u003c\/h4\u003e\n\u003cp\u003e\nNo natural gas? A factory \u003cstrong\u003eLP conversion kit\u003c\/strong\u003e is available (use up to \u003cstrong\u003e2,000 ft\u003c\/strong\u003e elevation), giving homeowners flexibility where propane is the primary fuel.\n\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cspan style=\"color: #3366ff;\"\u003e\u003ca href=\"https:\/\/s3-us-west-2.amazonaws.com\/catsy.782\/CGS-C+IO.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eInstallation and Operation Manual\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"color: #3366ff;\"\u003e\u003ca href=\"https:\/\/s3-us-west-2.amazonaws.com\/catsy.782\/CGS-C+Steam+Series+Product+Specifications.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eSpec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"color: #3366ff;\"\u003e\u003ca href=\"https:\/\/s3-us-west-2.amazonaws.com\/catsy.782\/New+Yorker+Limited+Warranty.pdf\" target=\"_blank\"\u003e\u003cspan style=\"color: #3366ff;\"\u003eWarranty\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"New Yorker","offers":[{"title":"Default Title","offer_id":43935261065267,"sku":"BURCGS70CNIH","price":5364.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcgs60cnih__1.png?v=1770280187"},{"product_id":"new-yorker-cg40fn-gh-cg-40-dni-g2-96-000-btu-hot-water-boiler","title":"New Yorker CG40FN-GH (CG 40 DNI-G2) 96,000 BTU Hot Water Boiler","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CG40FN-GH (CG 40 DNI-G2) 96,000 BTU Cast-Iron Hot Water Gas Boiler\u003c\/h2\u003e\n\u003cp\u003e\nLooking for dependable \u003cstrong\u003eresidential steam heat\u003c\/strong\u003e for cast-iron radiators? The \u003cstrong\u003eNew Yorker CGS40-CNIH\u003c\/strong\u003e is a compact, \u003cstrong\u003egas-fired steam boiler\u003c\/strong\u003e built for reliability and easy service. With an \u003cstrong\u003e82% AFUE\u003c\/strong\u003e, durable \u003cstrong\u003ecast iron heat exchanger\u003c\/strong\u003e, and a factory vent damper for better efficiency, this \u003cstrong\u003e105,000 BTU class\u003c\/strong\u003e model delivers steady, even steam while keeping ownership simple for homeowners and contractors.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS40-CNIH (CGS40ANI-ME2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas-Fired Steam Boiler\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (field-convertible to LP with kit up to 2,000 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e 103,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e 84,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e 82%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent), with factory vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Chimney vent; built-in draft diverter (recommended min. chimney 5\" × 15 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger:\u003c\/strong\u003e Cast Iron Sections with Metal Section Connectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Content:\u003c\/strong\u003e 6.5 gal (steamable volume 5.0 gal)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e 2\" steam supply \/ 2\" return; 1\/2\" NPT gas; 5\" flue collar\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 16\" × 28\" × 40-7\/16\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10-Year Limited Heat Exchanger Warranty (residential)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eReliable Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003e\nThe CGS40-CNIH uses a \u003cstrong\u003ecast iron heat exchanger\u003c\/strong\u003e for long service life in a steam environment. Metal section connectors and an insulated jacket help maintain efficiency and durability through years of winter use.\n\u003c\/p\u003e\n\n\u003ch4\u003eProven Steam Performance\u003c\/h4\u003e\n\u003cp\u003e\nRated at \u003cstrong\u003e63,000 BTU\/h Net IBR\u003c\/strong\u003e, this model delivers consistent steam for typical small-to mid-size homes. Its \u003cstrong\u003e82% AFUE\u003c\/strong\u003e efficiency and factory \u003cstrong\u003event damper\u003c\/strong\u003e reduce standby losses compared to older boilers.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple Chimney Venting\u003c\/h4\u003e\n\u003cp\u003e\nAs a \u003cstrong\u003eCategory I natural-draft\u003c\/strong\u003e boiler with a built-in draft diverter, the CGS40-CNIH installs on a standard lined masonry or listed metal chimney. Recommended minimum chimney size is \u003cstrong\u003e5\" diameter × 15 ft\u003c\/strong\u003e height.\n\u003c\/p\u003e\n\n\u003ch4\u003eElectronic Ignition \u0026amp; Safety Controls\u003c\/h4\u003e\n\u003cp\u003e\nAn \u003cstrong\u003eelectronic (intermittent) ignition\u003c\/strong\u003e lights the burner only when needed. Standard safety components include a \u003cstrong\u003eprobe-type low water cut-off\u003c\/strong\u003e, \u003cstrong\u003epressure limit control\u003c\/strong\u003e, and a \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e to help protect the system.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller-Friendly Piping \u0026amp; Layout\u003c\/h4\u003e\n\u003cp\u003e\nWith \u003cstrong\u003e2\" steam supply\/return\u003c\/strong\u003e tappings, clear front\/side access, and a compact 16\" width, the CGS40-CNIH makes near-boiler piping and service straightforward. An optional \u003cstrong\u003enear-boiler piping kit\u003c\/strong\u003e is available for clean, code-compliant layouts.\n\u003c\/p\u003e\n\n\u003ch4\u003eLP Conversion Option\u003c\/h4\u003e\n\u003cp\u003e\nRunning propane? A factory \u003cstrong\u003eLP conversion kit\u003c\/strong\u003e is available for this model (use at elevations up to 2,000 ft). That flexibility is handy for homes without natural gas service.\n\u003c\/p\u003e\n\n\u003ch3\u003eAdditional Features Contractors Appreciate\u003c\/h3\u003e\n\u003cp\u003e\nFully packaged design; insulated jacket to cut standby loss; blocked-vent and rollout safety switches; vent damper and draft hood included; clear tapping locations; and thorough documentation for sizing, venting, start-up, and maintenance. Pair with the optional near-boiler piping kit for fast, repeatable installations.\n\u003c\/p\u003e\n\u003cp\u003e Want to learn more about this boiler? Read more about it in our article on \u003ca href=\"https:\/\/plumbing-deals.com\/blogs\/plumbing-blog\/the-best-steam-boilers-of-2025-a-comprehensive-guide\"\u003ethe best steam boilers.\u003c\/a\u003e\u003c\/p\u003e","brand":"New Yorker","offers":[{"title":"Default Title","offer_id":43935261327411,"sku":"BURCG40FNGH","price":3342.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcg70fngh__1_7cc89114-8167-4137-a388-75cd158255e7.png?v=1770280168"},{"product_id":"new-yorker-cg50-fngh-cg-50-dni-g2-130-000-btu-hot-water-boiler","title":"New Yorker CG50-FNGH (CG 50 DNI-G2) 130,000 BTU Hot Water Boiler","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CG50-FNGH (CG 50 DNI-G2) 130,000 BTU Cast-Iron Hot Water Gas Boiler\u003c\/h2\u003e\n\u003cp\u003e\nNeed dependable whole‑home heat with easy service? The \u003cstrong\u003eNew Yorker CG50\u003c\/strong\u003e is a compact,\n\u003cstrong\u003ecast‑iron, chimney‑vented hot water boiler\u003c\/strong\u003e with straightforward controls and proven durability—ideal for baseboard and radiator systems in small to mid‑size homes. An integrated control with a fuel‑saving \u003cstrong\u003ethermal purge\u003c\/strong\u003e routine helps trim standby losses, while electronic ignition fires only when there’s a call for heat.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CG50‑FNGH (CG 50 DNI‑G2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired, Non‑Condensing Hot Water Boiler\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available on select packages)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e \u003cstrong\u003e130,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Capacity:\u003c\/strong\u003e \u003cstrong\u003e108,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Water):\u003c\/strong\u003e \u003cstrong\u003e94,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e \u003cstrong\u003e84%\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent); step‑opening gas valve for smooth starts\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Category I, draft‑hood; \u003cstrong\u003e6\" flue\u003c\/strong\u003e to a lined masonry or listed metal chimney\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Connections:\u003c\/strong\u003e 1‑1\/4\" NPT supply \u0026amp; return\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e 1\/2\" NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz, 1‑phase\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~19\" × 32\" × 40\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Limited lifetime heat exchanger (residential); 1‑year parts (see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eReliable Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003e\nA heavy‑duty \u003cstrong\u003ecast‑iron heat exchanger\u003c\/strong\u003e and metal section connectors deliver long service life and consistent heat transfer—ideal for hydronic systems that run for decades.\n\u003c\/p\u003e\n\n\u003ch4\u003eFuel‑Saving Integrated Control\u003c\/h4\u003e\n\u003cp\u003e\nThe user‑friendly control includes an \u003cstrong\u003eenergy‑saving thermal purge\u003c\/strong\u003e that circulates residual warm water before firing the burner, helping reduce fuel use and chimney losses.\n\u003c\/p\u003e\n\n\u003ch4\u003eRight‑Sized For Typical Homes\u003c\/h4\u003e\n\u003cp\u003e\nWith a \u003cstrong\u003eNet IBR of about 94,000 BTU\/h\u003c\/strong\u003e, the CG50 is a solid match for many homes when properly sized to your radiation and heat loss.\n\u003c\/p\u003e\n\n\u003ch4\u003eSimple, Code‑Compliant Venting\u003c\/h4\u003e\n\u003cp\u003e\nThis \u003cstrong\u003eCategory I natural‑draft\u003c\/strong\u003e boiler connects to a properly sized, lined chimney with a standard \u003cstrong\u003e6‑inch flue\u003c\/strong\u003e. That makes replacements straightforward in homes with existing chimneys.\n\u003c\/p\u003e\n\n\u003ch4\u003eInstaller‑Friendly Layout\u003c\/h4\u003e\n\u003cp\u003e\nClear front\/side access, 1‑1\/4\" supply\/return tappings, and included vent damper simplify piping and annual service. Many packages ship with a familiar \u003cstrong\u003eTaco 007\u003c\/strong\u003e circulator to speed up installs.\n\u003c\/p\u003e","brand":"NEW YORKER","offers":[{"title":"Default Title","offer_id":43935293407283,"sku":"BURCG50FNGH","price":3732.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcg70fngh__1_cd384e75-df1a-4199-90fc-a76aa7a9b59f.png?v=1770280168"},{"product_id":"new-yorker-cg60-fngh-cg-60-dni-g2-164-000-btu-hot-water-boiler","title":"New Yorker CG60-FNGH (CG 60 DNI-G2) 164,000 BTU Hot Water Boiler","description":"Upgrade Your Home Comfort With The New Yorker CG60-FNGH (CG 60 DNI-G2) 164,000 BTU Cast-Iron Hot Water Gas Boiler\nNeed dependable whole‑home heat with easy service? The New Yorker CG60 is a compact, cast‑iron, chimney‑vented hot water boiler with straightforward controls and proven durability—ideal for baseboard and radiator systems. An integrated control with a fuel‑saving thermal purge routine helps trim standby losses, while electronic ignition fires only when there’s a call for heat.\n\nBrand: New Yorker\nMPN: CG60‑FNGH (CG 60 DNI‑G2)\nType: Gas‑Fired, Non‑Condensing Hot Water Boiler\nFuel: Natural Gas (LP conversion kit available)\nInput: 164,000 BTU\/h\nHeating Capacity: 135,000 BTU\/h\nNet IBR (Water): 117,000 BTU\/h\nAFUE: 82%\nIgnition: Electronic (intermittent); step‑opening gas valve for smooth starts\nVenting: Category I, draft‑hood; 6\" flue to a lined masonry or listed metal chimney\nWater Connections: 1‑1\/4\" NPT supply \u0026amp; return\nGas Inlet: 1\/2\" NPT\nElectrical: 120V, 60 Hz, 1‑phase\nIncluded: Integrated boiler control with thermal purge, factory vent damper; many packages include a Taco 007 circulator\nWarranty: Limited lifetime heat exchanger (residential); 1‑year parts (see terms)\nReliable Cast Iron Construction\nA heavy‑duty cast‑iron heat exchanger and metal section connectors deliver long service life and consistent heat transfer—ideal for hydronic systems that run for decades.\n\nFuel‑Saving Integrated Control\nThe user‑friendly control includes an energy‑saving thermal purge that circulates residual warm water before firing the burner, helping reduce fuel use and chimney losses.\n\nRight‑Sized For Mid‑Size Homes\nWith a Net IBR of about 117,000 BTU\/h, the CG60 is a solid match for many homes when properly sized to your radiation and heat loss.\n\nSimple, Code‑Compliant Venting\nThis Category I natural‑draft boiler connects to a properly sized, lined chimney with a standard 6‑inch flue. That makes replacements straightforward in homes with existing chimneys.\n\nInstaller‑Friendly Layout\nClear front\/side access, 1‑1\/4\" supply\/return tappings, and an included vent damper simplify piping and annual service. Many packages ship with a familiar Taco 007 circulator to speed up installs.\n\nInstallation and Operation Manual\n\nSpec Sheet\n\nWarranty\n\nThis boiler can be converted from natural gas to liquid propane with Burnham Boilers 110928-01 Natural Gas to Liquid Propane Conversion Kit (3-6 Section).","brand":"NEW YORKER","offers":[{"title":"Default Title","offer_id":43935294160947,"sku":"BURCG60FNGH","price":4547.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/342023_burcg50fnth.jpg?v=1771537296"},{"product_id":"new-yorker-cgs80-cnih-cgs-80-anc-fe-2-245-000-btu-steam-boiler","title":"New Yorker CGS80-CNIH (CGS 80 ANC-FE 2) 245,000 BTU Steam Boiler","description":"\u003ch2\u003eEnjoy Durable and Efficient Heating with the New Yorker CGS80-CNIH 245,000 BTU Steam Boiler \u003c\/h2\u003e\n\u003cp\u003eFor contractors seeking a reliable and efficient steam boiler for their clients, the New Yorker CGS80-CNIH (CGS 80 ANC-FE 2) 245,000 BTU Steam Boiler is an outstanding choice. This model combines robust performance with advanced features, making it an excellent option for residential heating needs. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS80CNI‑H (CGS‑C Steam Series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired \u003cstrong\u003eSteam\u003c\/strong\u003e Boiler, Cast Iron, Category I Natural Draft (Chimney Vent)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (LP conversion kit available)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e \u003cstrong\u003e241,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e \u003cstrong\u003e199,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNet IBR (Steam):\u003c\/strong\u003e \u003cstrong\u003e149,000 BTU\/h\u003c\/strong\u003e (≈ \u003cstrong\u003e621 sq. ft. EDR\u003c\/strong\u003e)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e \u003cstrong\u003e82.2%\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent) with factory \u003cstrong\u003event damper\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Built‑in draft diverter; \u003cstrong\u003e7\" flue\u003c\/strong\u003e to a lined masonry or listed metal chimney\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSteam Supply \/ Return Tappings:\u003c\/strong\u003e \u003cstrong\u003e2\"\u003c\/strong\u003e NPT (each)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Inlet:\u003c\/strong\u003e \u003cstrong\u003e3\/4\"\u003c\/strong\u003e NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Content:\u003c\/strong\u003e \u003cstrong\u003e12.1 gallons\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz; 15A fused\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e \u003cstrong\u003e30\" × 29\" × 40‑7\/16\"\u003c\/strong\u003e (cabinet)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety \u0026amp; Controls:\u003c\/strong\u003e Probe \u003cstrong\u003eLWCO\u003c\/strong\u003e, pressure limit control, \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e, blocked‑vent \u0026amp; rollout switches\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ASME H‑stamped; \u003cstrong\u003eAHRI\u003c\/strong\u003e and \u003cstrong\u003eETL\u003c\/strong\u003e listed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Limited residential heat‑exchanger warranty (see terms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cb\u003eHigh Efficiency:\u003c\/b\u003e The CGS80-CNIH is designed with efficiency and savings in mind, boasting an impressive AFUE (Annual Fuel Utilization Efficiency) rating of up to 82.2%. This high level of efficiency ensures optimal energy use, translating to reduced operational costs for homeowners. With lower fuel consumption and decreased energy bills, the CGS80-CNIH provides long-term value, making it a smart and eco-friendly choice. For contractors, this high AFUE rating is an attractive selling point, offering a reliable, cost-effective solution that meets the growing demand for energy-efficient heating systems. Homeowners can enjoy both comfort and savings, while contractors can confidently recommend a product that delivers lasting results. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDurable Construction:\u003c\/b\u003e Built with cast iron heat exchangers and stainless steel burners, this boiler is engineered for exceptional longevity and consistent performance. The cast iron construction ensures the boiler can withstand high temperatures and pressures, offering reliable heating for years to come. Its stainless steel burners are designed to resist corrosion and deliver efficient, consistent fuel combustion. New Yorker boilers are renowned for their durability, combining advanced engineering with high-quality materials to create systems that contractors can trust. Whether for residential or commercial applications, these boilers provide long-lasting heating solutions, making them a dependable choice for professionals seeking to deliver optimal results and satisfaction to their clients. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBuilt-In Draft Diverter:\u003c\/b\u003e The integrated draft diverter is thoughtfully designed to allow installation in low or compact spaces, making it a versatile and practical choice for a wide range of settings, including residential, commercial, or industrial applications. This feature not only enhances its adaptability but also plays a crucial role in maintaining proper ventilation by directing airflow effectively. By ensuring safe and efficient operation, the draft diverter helps prevent the buildup of harmful gases and promotes a more reliable and secure performance over time. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eElectronic Ignition:\u003c\/b\u003e This feature enhances reliability and ease of use, ensuring the boiler starts efficiently and consistently every time, even in varying conditions. The electronic ignition system replaces the traditional standing pilot light, which not only reduces the risk of malfunction but also significantly improves energy efficiency by eliminating the constant energy consumption of a continuously burning pilot. This modern approach ensures better performance, lower energy costs, and a more environmentally friendly operation for your heating system. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSafety Features:\u003c\/b\u003e Equipped with a pressure limit control, low water cut-off, and a pop safety valve, the CGS80-CNIH is designed to prioritize safety and provide peace of mind for both contractors and homeowners. These advanced safety mechanisms work together to prevent accidents by ensuring the boiler consistently operates within safe parameters. For example, the pressure limit control prevents the system from exceeding safe pressure levels, while the low water cut-off protects the boiler from running without sufficient water, which could cause damage. Additionally, the pop safety valve acts as a failsafe, releasing excess pressure when necessary to avoid potentially hazardous situations. The inclusion of these multiple safety features not only reduces the risk of accidents but also enhances the overall reliability and longevity of the boiler, making it a dependable choice for any home or project. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eComprehensive Warranty:\u003c\/b\u003e The CGS80-CNIH comes with a 10-year limited warranty, offering peace of mind and reliable support for both contractors and homeowners. This warranty ensures protection against potential defects, giving you confidence in the product's durability and long-term performance. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEase of Installation:\u003c\/b\u003e The built-in draft diverter and compact design make this boiler not only efficient but also incredibly easy to install, even in tight or awkward spaces. This user-friendly setup can save significant time during the installation process and reduce labor costs, which is a major advantage for contractors working on demanding schedules or budget-conscious projects. Its thoughtful design ensures that professionals can complete installations more smoothly, making it a practical and reliable choice for a wide range of applications. \u003c\/li\u003e\n\u003cli\u003eNew Yorker Boiler Company is a trusted name in the heating industry, known for manufacturing reliable residential heating products. With a history of producing high-quality, durable boilers, New Yorker continues to set the standard for performance and reliability. The CGS80-CNIH model exemplifies this commitment to excellence, offering a dependable solution for residential heating needs. \u003c\/li\u003e\n\u003cli\u003eIn conclusion, the New Yorker CGS80-CNIH (CGS 80 ANC-FE 2) 245,000 BTU Steam Boiler is an excellent choice for contractors seeking a dependable, efficient, and easy-to-install steam boiler for their clients. Its combination of high efficiency, durable construction, and advanced safety features makes it a standout option for 2025. \u003c\/li\u003e\n\n\u003ch3\u003eAdditional Features \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 82.2% AFUE \u003c\/li\u003e\n\u003cli\u003eAvailable for natural gas or liquid propane fuel \u003c\/li\u003e\n\u003cli\u003eElectronic ignition \u003c\/li\u003e\n\u003cli\u003eStainless steel burners \u003c\/li\u003e\n\u003cli\u003eMetal section connectors resist chemicals and increases the life of the boiler \u003c\/li\u003e\n\u003cli\u003eBuilt-in draft diverter fits in low spaces \u003c\/li\u003e\n\u003cli\u003eCast iron heat exchanger meets the ASME boiler and pressure vessel code \u003c\/li\u003e\n\u003cli\u003eStep-Opening Gas Valve allows for a smooth and quiet startup \u003c\/li\u003e\n\u003cli\u003eFully assembled \u003c\/li\u003e\n\u003cli\u003e10-year limited warranty \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Want to learn more about this steam boiler? Read more about it in our article on \u003ca href=\"https:\/\/plumbing-deals.com\/plumbing-blog\/buying-guides-steam-boilers\/\"\u003ethe best steam boilers.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eWant to learn more about this steam boiler? Check out our article on the\u003ca\u003eTop Steam Boilers for 2025\u003c\/a\u003e on our Resource Center!\u003c\/p\u003e","brand":"New Yorker","offers":[{"title":"Default Title","offer_id":43935294324787,"sku":"BURCGS80CNIH","price":5941.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcgs60cnih__1_ec80d46d-42d8-439e-8e9f-f235ba210d1c.png?v=1770280196"},{"product_id":"new-yorker-cgs50-cnih-cgs-50-ani-me-2-140-000-btu-steam-boiler","title":"New Yorker CGS50-CNIH (CGS 50 ANI-ME 2) 140,000 BTU Steam Boiler","description":"\u003ch2\u003eUpgrade Your Home Comfort With The New Yorker CGS-C CGS30CNI-H 70,000 BTU Cast-Iron Steam Boiler\u003c\/h2\u003e\n\u003cp\u003e\nWant big boiler performance without taking up floor space? The \u003cstrong\u003eVitodens 200‑W B2HA‑399\u003c\/strong\u003e is a \u003cstrong\u003ewall‑mounted, high‑efficiency gas condensing boiler\u003c\/strong\u003e built for larger homes and light‑commercial projects. It modulates smoothly from \u003cstrong\u003e113–399 MBH\u003c\/strong\u003e to match real‑world demand, and its \u003cstrong\u003eInox‑Radial stainless steel heat exchanger\u003c\/strong\u003e helps keep efficiency high season after season.\n\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Viessmann\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e B2HA‑399 (Vitodens 200‑W)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Wall‑Mounted, Condensing Gas Boiler\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas or LP (conversion kit available)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 113–399 MBH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Output (Typical):\u003c\/strong\u003e up to ~375 MBH\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e ~94%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModulation:\u003c\/strong\u003e Up to ~6.5:1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger:\u003c\/strong\u003e 316Ti Inox‑Radial Stainless Steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCombustion Control:\u003c\/strong\u003e Lambda Pro with Fully Modulating MatriX Cylinder Burner\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Direct‑vent sealed combustion or room‑air (per code)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVent Options:\u003c\/strong\u003e Concentric 100\/150 mm (≈4\"\/6\") or Two‑Pipe Systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMax Equivalent Vent Lengths:\u003c\/strong\u003e Generous runs (layout‑dependent; see manual)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeating Connections:\u003c\/strong\u003e 2\" NPT supply\/return\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGas Connection:\u003c\/strong\u003e 1\" NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 120V, 60 Hz\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControls:\u003c\/strong\u003e Vitotronic 200 (HO1B) with outdoor reset and diagnostics\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e ~23‑5\/8\" × 27\" × 44‑1\/2\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 0\" to combustibles at vent; service clearances per manual\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCascade Capability:\u003c\/strong\u003e Common‑vent\/manifold options; up to 8 boilers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eHigh Efficiency, Clean Combustion\u003c\/h4\u003e\n\u003cp\u003e\nThe fully modulating \u003cstrong\u003eMatriX cylinder burner\u003c\/strong\u003e and \u003cstrong\u003eLambda Pro\u003c\/strong\u003e combustion control keep the air‑to‑fuel mix dialed in—even when gas quality varies—helping the system run efficiently and cleanly.\n\u003c\/p\u003e\n\n\u003ch4\u003eBig Output, Right‑Sized Modulation\u003c\/h4\u003e\n\u003cp\u003e\nWith \u003cstrong\u003e113–399 MBH\u003c\/strong\u003e input and up to \u003cstrong\u003e~6.5:1\u003c\/strong\u003e modulation, the 200‑W can idle on \u003cstrong\u003emilder spring\/fall days\u003c\/strong\u003e and ramp up for peak demand. That reduces short‑cycling, improves comfort, and helps components last.\n\u003c\/p\u003e\n\n\u003ch4\u003eCompact, Wall‑Hung Footprint\u003c\/h4\u003e\n\u003cp\u003e\nA cabinet roughly \u003cstrong\u003e24\" wide × 27\" deep × 44‑1\/2\" high\u003c\/strong\u003e saves floor space in tight mechanical rooms. Front‑access design keeps annual service straightforward for your contractor.\n\u003c\/p\u003e\n\n\u003ch4\u003eFlexible Venting For Retrofits\u003c\/h4\u003e\n\u003cp\u003e\nChoose \u003cstrong\u003econcentric 100\/150 mm (≈4\"\/6\")\u003c\/strong\u003e or \u003cstrong\u003etwo‑pipe\u003c\/strong\u003e systems with generous equivalent lengths. Use direct‑vent sealed combustion or draw room air where code allows.\n\u003c\/p\u003e\n\n\u003ch4\u003eOutdoor‑Reset Intelligence\u003c\/h4\u003e\n\u003cp\u003e\nThe integrated \u003cstrong\u003eVitotronic 200\u003c\/strong\u003e control with \u003cstrong\u003eoutdoor reset\u003c\/strong\u003e automatically adjusts water temperature to the weather, helping lower fuel use while keeping rooms comfortable.\n\u003c\/p\u003e\n\n\u003ch4\u003eCascade‑Ready For Larger Loads\u003c\/h4\u003e\n\u003cp\u003e\nNeed more capacity? Manifold up to \u003cstrong\u003eeight Vitodens 200‑W\u003c\/strong\u003e units with common venting. The system stages boilers only as needed to match the load and maintain high efficiency.\n\u003c\/p\u003e","brand":"NEW YORKER","offers":[{"title":"Default Title","offer_id":43935294423091,"sku":"BURCGS50CNIH","price":4565.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcgs50cnih__1.png?v=1770280187"},{"product_id":"new-yorker-cgs40-cnih-cgs-40-ani-me-2-105-000-btu-steam-boiler","title":"New Yorker CGS40-CNIH (CGS 40 ANI-ME 2) 105,000 BTU Steam Boiler","description":"\u003ch2\u003eNew Yorker CGS40‑CNIH (CGS 40 ANI‑ME 2) 105,000 BTU Gas‑Fired Steam Boiler\u003c\/h2\u003e\n\u003cp\u003e\nLooking for dependable \u003cstrong\u003eresidential steam heat\u003c\/strong\u003e for cast‑iron radiators? The \u003cstrong\u003eNew Yorker CGS40‑CNIH\u003c\/strong\u003e is a compact, \u003cstrong\u003egas‑fired steam boiler\u003c\/strong\u003e built for reliability and easy service. With an \u003cstrong\u003e82% AFUE\u003c\/strong\u003e, durable \u003cstrong\u003ecast iron heat exchanger\u003c\/strong\u003e, and a factory vent damper for better efficiency, this \u003cstrong\u003e105,000 BTU class\u003c\/strong\u003e model delivers steady, even steam while keeping ownership simple for homeowners and contractors.\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e New Yorker\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMPN:\u003c\/strong\u003e CGS40‑CNIH (CGS40ANI‑ME2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Gas‑Fired Steam Boiler\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuel:\u003c\/strong\u003e Natural Gas (field‑convertible to LP with kit up to 2,000 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInput (NG):\u003c\/strong\u003e 103,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDOE Heating Capacity:\u003c\/strong\u003e 84,000 BTU\/h\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAFUE:\u003c\/strong\u003e 82%\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e Electronic (intermittent), with factory vent damper\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVenting:\u003c\/strong\u003e Chimney vent; built‑in draft diverter (recommended min. chimney 5\" × 15 ft)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Exchanger:\u003c\/strong\u003e Cast Iron Sections with Metal Section Connectors\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater Content:\u003c\/strong\u003e 6.5 gal (steamable volume 5.0 gal)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e 2\" steam supply \/ 2\" return; 1\/2\" NPT gas; 5\" flue collar\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDimensions (W × D × H):\u003c\/strong\u003e 16\" × 28\" × 40‑7\/16\"\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10‑Year Limited Heat Exchanger Warranty (residential)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReliable Cast Iron Construction\u003c\/h4\u003e\n\u003cp\u003eThe CGS40‑CNIH uses a \u003cstrong\u003ecast iron heat exchanger\u003c\/strong\u003e for long service life in a steam environment. Metal section connectors and an insulated jacket help maintain efficiency and durability.\u003c\/p\u003e\n\u003ch4\u003eProven Steam Performance\u003c\/h4\u003e\n\u003cp\u003eRated at \u003cstrong\u003e63,000 BTU\/h Net IBR\u003c\/strong\u003e (≈263 sq. ft. EDR), this model delivers consistent steam for typical small‑ to mid‑size homes. Its \u003cstrong\u003e82% AFUE\u003c\/strong\u003e and factory \u003cstrong\u003event damper\u003c\/strong\u003e reduce standby losses compared to older boilers.\u003c\/p\u003e\n\u003ch4\u003eSimple Chimney Venting\u003c\/h4\u003e\n\u003cp\u003eAs a \u003cstrong\u003eCategory I natural‑draft\u003c\/strong\u003e boiler with a built‑in draft diverter, the CGS40‑CNIH installs on a standard lined masonry or listed metal chimney. Recommended minimum chimney size is \u003cstrong\u003e5\" diameter × 15 ft\u003c\/strong\u003e height.\u003c\/p\u003e\n\u003ch4\u003eElectronic Ignition \u0026amp; Safety Controls\u003c\/h4\u003e\n\u003cp\u003eAn \u003cstrong\u003eelectronic (intermittent) ignition\u003c\/strong\u003e lights the burner only when needed. Standard safety components include a \u003cstrong\u003eprobe‑type low water cut‑off\u003c\/strong\u003e, \u003cstrong\u003epressure limit control\u003c\/strong\u003e, and a \u003cstrong\u003e15 psi safety valve\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eInstaller‑Friendly Piping \u0026amp; Layout\u003c\/h4\u003e\n\u003cp\u003eWith \u003cstrong\u003e2\" steam supply\/return\u003c\/strong\u003e tappings, clear front\/side access, and a compact 16\" width, the CGS40‑CNIH makes near‑boiler piping and service straightforward. An optional \u003cstrong\u003enear‑boiler piping kit\u003c\/strong\u003e is available for clean, code‑compliant layouts.\u003c\/p\u003e\n\u003ch4\u003eLP Conversion Option\u003c\/h4\u003e\n\u003cp\u003eRunning propane? A factory \u003cstrong\u003eLP conversion kit\u003c\/strong\u003e is available (use at elevations up to 2,000 ft).\n\u003c\/p\u003e","brand":"New Yorker","offers":[{"title":"Default Title","offer_id":43935294259251,"sku":"BURCGS40CNIH","price":4106.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/files\/burcgs60cnih__1_b823e376-f948-42b0-b529-2273ba7416ed.png?v=1770280187"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5964\/8563\/collections\/new-yorker-boiler-logo-1_1540471980__24446.original.jpg?v=1771893765","url":"https:\/\/plumbing-deals.com\/collections\/new-yorker.oembed","provider":"Plumbing Deals","version":"1.0","type":"link"}